Advisories

Delta Electronics DIAEnergie SQL Injection via settings group-list hid Parameter

Go Back
severity
high
date
Affecting
  • DIAEnergie < 1.11.00.022

CWE
  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVSS
8.7
CVSS V4 Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Credit
Alex Williams from Pellera Technologies
Description
Delta Electronics DIAEnergie before 1.11.00.022 contains a SQL injection vulnerability in the settings group-list action that allows remote authenticated attackers to manipulate database contents by injecting unsanitized input through the hid parameter, which is concatenated directly into a single-quoted WHERE subquery without parameterization or escaping. Attackers can leverage time-based and stacked-query payloads through the permissive global request filter to read, modify, and delete database contents, and escalate to operating-system command execution when the configured database account is sufficiently privileged.